Solution
To ensure that lines in CAD drawings are printed at exactly the right length, use [Adjust Length] to adjust the amount that paper is advanced.
There are two options in [Adjust Length] : [AdjustmentPrint] and [Change Settings].
After a test pattern is printed, you will measure the discrepancy based on the results of printing.
No test pattern is printed. Instead, you will measure a document already printed to determine the discrepancy.
Additionally, two modes are available in both [AdjustmentPrint] and [Change Settings] : [A:High] or [B:Standard/Draft]. Choose the mode that suits your particular printing application.
This setting is applied when [Highest quality] or [High] is selected in [Print Quality] in the printer driver.
This setting is applied when [Standard] or [Fast] is selected in [Print Quality] in the printer driver.
NOTE
- Always check the [Adj. Priority] values before using [Adjust Length].
- Use paper of the same type and size for adjustment as you will use for printing.
<Paper to Prepare>
When Using Rolls:
- An unused roll at least 10 inches wide
- High-precision ruler
When Using Sheets:
- One sheet of unused paper of at least A4/Letter size
- High-precision ruler
Perform adjustment as follows.
1.Load the paper.
IMPORTANT
- Always make sure the loaded paper matches the type of paper specified. Adjustment cannot be completed correctly unless the loaded paper matches the settings.
2.On the [Tab Selection screen] of the Control Panel, press

or

to select the Settings/Adj. tab (

).
NOTE
- If the [Tab Selection screen] is not displayed, press the [Menu] button.
3.Press the [OK] button.
The [Set./Adj. Menu] is displayed.
4.Press

or

to select [Adjust Printer], and then press the [OK] button.
5.Press

or

to select [Feed Priority], and then press the [OK] button.
6.Press

or

to select [Adjust Length], and then press the [OK] button.
7.Press

or

to select [AdjustmentPrint] or [Change Settings], and then press the [OK] button.
When you select [AdjustmentPrint], a test pattern is printed for you to measure the scale and calculate the discrepancy. The scale bar shows [Millimeter] in 50 mm units and [Inch] in 1 inch units.
NOTE
- A test pattern is printed in black when you choose [A:High] or in magenta if you choose [B:Standard/Draft].
- To cancel printing the test pattern for adjustment, hold down the [Stop] button. When "[Stop printing?]" is displayed, press
or
to select "[Yes]", and then press the [OK] button.
8.Press

or

to enter the amount of discrepancy, and then press the [OK] button.
If the scale is shorter than the actual size, use a positive setting value. If it is longer, use a negative value.
The feed amount can be adjusted in 0.02% increments.